Are you looking to switch your Generac standby generator from LP (liquid propane) to NG (natural gas)? You’re in the right place!
Converting your generator can save you money and ensure you’re never left in the dark. Plus, with natural gas, you get a cleaner, more efficient energy source. Imagine the peace of mind knowing your home is powered by a reliable energy source, especially during unexpected outages.
In this guide, we’ll break down the conversion process into simple, actionable steps. You’ll discover tips, tools, and expert advice to make the transition smooth and stress-free. Ready to ensure your home stays powered, no matter what? Let’s dive in and get started!
Tools And Materials Needed
Gathering the right tools and materialsis key. You will need:
- A wrench setfor loosening and tightening bolts.
- A screwdriverto remove panels and screws.
- Pipe wrenchto disconnect and connect gas lines safely.
- Thread sealantdesigned for gas connections.
- A conversion kitspecific to your Generac model.
- Gas regulatorcompatible with natural gas.
- Protective glovesto keep hands safe.
- Safety gogglesto protect eyes from debris.
Before starting, check the generator manualfor any special parts or instructions.

Credit: www.youtube.com
Safety Precautions
Always turn offthe generator and disconnect powerbefore starting. Gas leaks can cause fires or explosions. Work in a well-ventilated areato avoid breathing harmful fumes. Use proper toolsand wear safety glovesand eye protection.
Double-check all connections for tightness to prevent leaks. Never smoke or use open flames near the generator. Keep a fire extinguishernearby for emergencies. Follow the manufacturer’s instructionsexactly to avoid damage or injury.
Locate The Fuel Conversion Kit
The fuel conversion kitis needed to switch your Generac generator from LP to NG. This kit includes parts like:
- Orifice adapter– changes fuel flow
- Regulator– controls gas pressure
- Instruction manual– guides installation
Find the kit inside the generator’s access panel or box. It may be labeled “LP to NG Conversion Kit.”Check the model number on the kit matches your generator’s model. This ensures compatibility.
Keep the kit on hand before starting the switch. Missing parts can delay the process.
Shut Off The Generator
Turn off the generator before starting any work. Make sure it is completely shut downto avoid accidents. Disconnect the power supply to prevent any electrical shocks. Let the engine cool down to protect your hands from burns. Locate the fuel shut-off valveand close it to stop gas flow. Check the control panel to confirm the generator is off. Safety first. Never try to convert while the generator is running.
Remove Lp Components
Start by turning offthe generator and closing the LP gas valve. Carefully disconnect the LP fuel linefrom the generator. Use proper tools to avoid damage or leaks. Keep a container ready to catch any fuel that might spill.
Next, locate the LP regulatorand remove it. This part controls the gas pressure and must be taken off to switch to natural gas. Unscrew all connectors and set the regulator aside.
Finally, detach the LP carburetor parts. These include the carburetor and any fittings designed for LP gas. Removing these parts is essential before installing NG components. Handle all parts with care to avoid damage.
Install Ng Components
Attach the NG regulatorto control natural gas flow. This part replaces the LP regulator. Ensure tight fittings to avoid leaks. Use pipe sealant made for gas connections.
Connect the NG fuel linefrom the gas source to the regulator. Check the hose for cracks or damage before use. Secure connections with clamps for safety.
Replace the carburetor jets with ones designed for natural gas. This lets the engine burn natural gas efficiently. Use the correct jet size from the generator manual.
Adjust The Air Shutter
Adjusting the air shutteris key when converting a Generac standby generator from LP to NG. The air shutter controls the fuel-to-air ratiofor proper combustion. First, locate the air shutter near the carburetor or fuel mixer. Loosen the locking screwto move the shutter.
Open the shutter wider to allow more air for natural gas. Tighten the screw once set. Too little air causes poor engine performance. Too much air can lead to rough runningor stalling.
It is important to test the generatorafter adjustment. Listen for smooth operation and steady RPM. Repeat the adjustment if needed for the best balance between fuel and air.

Credit: www.ebay.com
Check And Tighten Connections
Check all gas connectionsfor leaks or loose fittings. Tighten every connection carefully to avoid gas leaks. Use a wrench that fits well to prevent damage.
Look at the electrical connectionstoo. Make sure wires are secure and not frayed. Loose wires can cause the generator to stop working.
Inspect the fuel lines. They must be tight and not cracked. Replace any damaged lines before use.
Use a soapy water solutionto test for leaks. Apply it to connections and watch for bubbles. Bubbles mean a leak is present and needs fixing.
Test The Generator Operation
Start the generator by switching it on. Listen for any unusual sounds.
Watch the control panel for error messages. The generator should run smoothly.
- Check fuel pressure to ensure proper flow.
- Observe the exhaust for smoke or strange smells.
- Make sure the generator reaches full power.
Look carefully around fuel connections for leaks. Use a flashlight if needed.
Smell for any gas odors near the tank and pipes.
Fix any leaks before running the generator longer. Safety first.

Credit: www.ebay.ca
Troubleshooting Common Issues
Check fuel supply. Ensure the natural gas line is open and connected correctly. A closed valve or loose fitting stops gas flow.
Inspect the regulator. The generator needs a regulator suited for natural gas. Using the wrong regulator causes pressure problems.
- Look for leaks.Use soapy water on connections. Bubbles show leaks that must be fixed.
- Verify spark plug condition.A fouled or worn spark plug can prevent starting.
- Review conversion kit installation.Parts must be installed exactly as the instructions say.
Check error codeson the generator display. Codes help find specific issues quickly.
Clean or replace air filters. Dirty filters reduce engine performance and cause problems starting.
Double-check all wiring and connections. Loose wires can cause malfunctions.
Frequently Asked Questions
How Do I Convert Generac Generator From Lp To Ng?
To convert a Generac generator from LP to NG, use a conversion kit. This kit includes orifices and regulators designed for natural gas. Follow the manufacturer’s instructions carefully for safe installation and proper functionality.
What Tools Are Needed For Lp To Ng Conversion?
Basic tools include a wrench set, screwdriver, and pipe thread sealant. Also, have a gas pressure gauge handy for testing. Always ensure safety gear is worn during the conversion process.
Is Professional Help Required For The Conversion?
While some can convert the generator themselves, professional help is recommended. Licensed technicians ensure correct installation and adherence to local gas codes, minimizing risk and ensuring optimal generator performance.
How Does The Fuel Type Affect Generator Performance?
Natural gas burns cleaner than LP, offering longer engine life. However, NG has lower energy content, so slight power differences may occur. Proper adjustment during conversion ensures efficient and reliable operation.
Conclusion
Converting your Generac standby generator from LP to NG is simple with the right steps. Always follow the instructions carefully to ensure safety. Use the correct tools and parts for the best results. Double-check all connections before testing the generator.
This switch can help you save money and use a cleaner fuel source. Stay patient and work slowly to avoid mistakes. Your generator will run smoothly on natural gas after the conversion. Keep maintenance in mind to extend its life.
This guide makes the process clear and easy to follow.